Fitmore hip stem
WebThe Fitmore® hip stem (Zimmer, Warsaw, Ind) is a bone-conserving stem designed for use in MIS techniques. The technique described here is a single-incision anterior approach with the Fitmore system using a special orthopedic table. MeSH terms Arthroplasty, Replacement, Hip / methods* Hip Joint / diagnostic imaging ... WebThe Zimmer femoral stems and necks are metal alloy implants used for hip replacements that allow the surgeon to fit the implant specifically to the patient. During hip replacement surgery, the damaged portions of the …
Fitmore hip stem
Did you know?
WebThe Zimmer Biomet primary hip portfolio encompasses femoral and acetabular systems, instruments and support services to address the distinct needs of individual patients, while simplifying the surgical workflow. ... Fitmore® Hip Stem. CPT® 12/14 Femoral System. Avenir® Hip System. Acetabular Reconstruction. G7 ® Acetabular System. WebThe aims of this study were to identify whether the bone mineral density (BMD) of the proximal femur increases following hip revision with a metaphyseal-fixation femoral stem and to identify the factors associated with BMD recovery. Methods: This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal ...
Web5 Fitmore Hip System - Ordering Information Fitmore General Instrument Set Product Description Size Quantity Product Number Fitmore Curved Hand Rasp – 1 00-7942-020 … WebApr 1, 2024 · The shorter stemmed prostheses (Fitmore(®) and our stem) performed better than the longer stemmed prosthesis (VerSys(®)). Conclusions: This is the first study to investigate the femoral ...
WebSep 23, 2024 · The Fitmore ® hip stem shows a high primary stability comparable to straight stem systems . The survival rate of the Fitmore ® hip stem after 8.6 years is reported with 99.6% (95% CI 97.1–99.9%) for the endpoint of “stem revision due to aseptic loosening”. However, the long-term impact of a low Canal Fill Index because of a high … WebApr 18, 2011 · Fitmore® Hip Stem Manufacturing Process . HCP Content Posted April 18, 2011 in Manufacturing Videos
WebProvide accessible, affordable, high quality, specialized orthopaedic services, physical medicine, rehabilitation, and physical and occupational therapy services that meet the needs of our community. Motivate and educate patients and their families to achieve an optimal level of functioning. Be a leader in supporting and sponsoring community ... on the fragility of defi lendingWebExplore más de 120,000 registros de retiros, alertas y notificaciones de seguridad de dispositivos médicos y sus conexiones con los fabricantes. ions of bismuthWebIn 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively CONCLUSION: Digital templating for the Fitmore ® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing ... on the frameWebDec 20, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option . A cementless titanium press-fit cup with or without screws ... ions of berylliumWebJan 6, 2016 · The Fitmore Hip Stem (Zimmer, Winterthur, Switzerland) is a curved, uncemented triple-tapered stem made from titanium alloy. Proximally, it has a titanium vacuum plasma spray coating, while the distal part is rough-blasted. The anchorage concept is based on apposition to the calcar supported by the medial curvature, which is available … on the fourth thursday in novemberWebOct 10, 2024 · Class 2 Device Recall FITMORE HIP STEM. All product manufactured prior to January 2014. Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). The firm distributed Urgent Medical Device Correction letters to customers on October 10, 2024. The letter informed customers that the previous version … on the fractional-order memristor modelWebJan 1, 2016 · Fitmore Hip Stem saving the bone mass in the area of greater trochanter and diaphysis of . the femur. It has different curves in order to restore the hip joint anatomy and achieve a . ions of any element have a full valence shell